Home > Products > Spectrometer > Echelle spectrometer

ARYELLE Butterfly

Related Applay:

Two separate spectral ranges

High spectral resolution

Suitable with various detectors

High light throughput

The high-performance wide-range double echelle spectrograph provides two separate spectral setups for the VUV and UV-VIS-NIS ranges, each with 400 mm focal length and one shared detector – maximum flexibility for precise elemental analysis with LIBS and Raman spectroscopy.

166 000 75669HOTLINE
WeChat Service

Introduction

  • SETUP

The ARYELLE Butterfly is a unique double echelle spectrograph of the ARraY echELLE series. It combines two separate ARYELLE 400 spectrometers that sequentially illuminate one shared detector in a compact housing – a cost-efficient solution covering a wide spectral range with a very high spectral resolution. Thus provides the opportunity to measure with two-dimensional echelle spectra in the VUV and UV-VIS-NIR range with an enormous variability. Each spectrometer part of the ARYELLE Butterfly features an aperture of f/10 and a focal length of 400 mm. The dispersion unit with echelle grating, prism, imaging optics and entrance slit can individually be adapted to nearly all customer applications depending on the required simultaneously detectable wavelength range and spectral resolution. By exclusively applying a CaF2 prism and reflection optics with broad-band UV coatings, chromatic aberrations are avoided.


Various CCD and ICCD cameras are suitable for the designed detection area of 27 x 27 mm². The light coupling into the ARYELLE Butterfly spectrometer is realized via SMA fiber for the UV-VIS-NIR range or via pure reflection transfer optics for the VUV range. Automatic recalibration of the wavelength scale is provided by a mercury lamp and an internal shutter.

The supplied operating software Sophi with optional LabVIEW library allows fully control of all spectrometer-detector functions via graphic user interface and provides automated measurement routines with an integrated scripting language. All lines of the gained spectrum are automatically analyzed with the integrated atomic spectra data base and qualitatively assigned to the corresponding elements. Quantitative analysis is based on calibration with reference materials.

  • SPECIFICATIONS

Optical designechelle spectrograph
Aperturef/10
Focal length400 mm
Slit width50 µm
Absolute accuracyspectral resolution / 4
Dynamic range15 bit, A/D conversion 16 bit
Light couplingSMA fiber coupling or mirror optics
Wavelength calibrationwith mercury lamp
ComputerPC incl. TFT or laptop with Microsoft Windows
SoftwareSophi, LabVIEW library optional
Dimensions without detector (L x W x H)(450 x 280 x 240) mm
Weight without detector20 kg

 

Setup123
DetectorCCDCCDICCD
Wavelength range1190-330 nm / 330-850 nm190-405 nm / 400-930 nm192-433 nm / 425-750 nm
Spectral resolving power λ/min. measurable FWHM130,000 / 15,00045,000 / 37,50014,000 / 20,000
Spectral resolution1,26-11 pm / 22-57 pm4.2-9 pm / 11-25 pm13-31 / 21-37 pm
Detector resolution2,048 x 512 px2,048 x 2,048 px1,024 x 1,024 px
Image area27.6 x 6.9 mm²27.6 x 27.6 mm²13.3 x 13.3 mm²
Chopperyesyesno
Step width, min.0.1 µs0.1 µs1 ns
Gate width5 ns

 

1 Depending on the chosen grating and prism, other ranges possible (down to 175 nm)
2 Depending on the slit width, other widths possible

Other spectral resolutions, wavelength ranges, CCD and ICCD detectors on request
Subject to technical changes without notice

  • APPLICATIONS